Difference between revisions of "Diesel Version 5:CV 19"

From Train Control Systems Documentation
Jump to navigation Jump to search
(Created page with "== NMRA CV 17 (Consist Address) == Contains a seven bit address in bit positions 0-6. Bit 7 indicates the relative direction of this unit within a consist, with a value of "0...")
 
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
== NMRA CV 17  (Consist Address) ==
 
Contains a seven bit address in bit positions 0-6. Bit 7 indicates the relative direction of this unit within a consist, with a value of "0" indicating normal direction, and a value of "1" indicating a direction opposite the unit's normal direction. If the seven bit address in bits 0-6 is "0000000" the unit is not in a consist.
 
 
 
{{Infobox
 
{{Infobox
|title = NMRA C 19
+
|title = NMRA CV 19
|header1 = Consist Address  
+
|header1 = Consist Address
|label2 = 0-255
+
|label2 = Range of Values
|data2 = RANGE OF VALUES HERE
+
|data2 = 0-255
 
|label3 = Default Value
 
|label3 = Default Value
|data3 = DEFAULT VALUE
+
|data3 = 0
 
}}
 
}}
 +
 +
== NMRA CV 19 - Consist Address ==
 +
This CV can be used to assign a second primary address to a locomotive for use in a consist, or "MU" arrangement. A value of 0 in this CV will disable the consist address. the consist address is made up of 7-bits, with Bit 7 indicating the relative direction of the unit within the consist. Values from 1 to 127 will operate the decoder on that address in the ''forward'' direction. An added value of 128 will ''reverse'' the operational direction.
 +
<br><br/>
 +
'''Example'''
 +
<br><br/>
 +
The desired consist address is 10. One unit will be operating in forward, one unit will be operating in reverse. For the forward facing unit, CV 19 should be programmed with a value of 10. For the reverse facing unit, CV 19 should be programmed with a value of 138 (128 + 10).
 +
<br><br/>
 +
''' Related: '''
 +
* [[{{NAMESPACE}}:CV_21|Consist Lighting (Part 1)]]
 +
* [[{{NAMESPACE}}:CV_22|Consist Lighting (Part 2)]]
 +
* [[{{NAMESPACE}}:CV_23|Consist Acceleration Adjustment]]
 +
* [[{{NAMESPACE}}:CV_24|Consist Deceleration Adjustment]]
 +
* [[{{NAMESPACE}}:CV_156|Dual Prime Mover Delay]]

Latest revision as of 17:07, 2 October 2018

NMRA CV 19
Consist Address
Range of Values0-255
Default Value0

NMRA CV 19 - Consist Address

This CV can be used to assign a second primary address to a locomotive for use in a consist, or "MU" arrangement. A value of 0 in this CV will disable the consist address. the consist address is made up of 7-bits, with Bit 7 indicating the relative direction of the unit within the consist. Values from 1 to 127 will operate the decoder on that address in the forward direction. An added value of 128 will reverse the operational direction.

Example

The desired consist address is 10. One unit will be operating in forward, one unit will be operating in reverse. For the forward facing unit, CV 19 should be programmed with a value of 10. For the reverse facing unit, CV 19 should be programmed with a value of 138 (128 + 10).

Related: