{{Infobox | {{Infobox | ||
|title = NMRA | |title = NMRA CV 23 | ||
|header1 = Acceleration Adjustment | |header1 = Consist Acceleration Adjustment | ||
|label2 = | |label2 = Range of Values | ||
|data2 = | |data2 = 0-255 | ||
|label3 = Default Value | |label3 = Default Value | ||
|data3 = | |data3 = 0 | ||
}} | }} | ||
== NMRA CV 23 - Consist Acceleration Adjustment == | |||
This CV contains additional acceleration rate information that is to be added to or subtracted from the base value contained in Configuration Variable #3. This CV will only affect the momentum when CV19 is a non-0 value, meaning the decoder is configured for advanced consisting. The total momentum value can be calculated using the following formula: | |||
<br><br/> | |||
([the contents of CV#23] multiplied by [0.896]) divided by (number of speed steps in use) | |||
<br><br/> | |||
This is a 7 bit value (bits 0-6) with bit 7 being reserved for a sign bit (0-add, 1-subtract). The product of this formula is added to the value in CV 3. In case of overflow (CV23 + CV3 > 255), the maximum acceleration rate shall be used (255). In case of underflow (CV3 + (-)CV23 < 0) no acceleration shall be used (0). The expected use of this configuration is for changing momentum to simulate differing train lengths/loads. Consisted/MU's tend to pull/push more cars, and therefore can have simulated higher loads by using this configuration. | |||
<br><br/> | |||
''' Related: ''' | |||
* [[{{NAMESPACE}}:CV_19|Consist Address]] | |||
* [[{{NAMESPACE}}:CV_21|Consist Lighting (Part 1)]] | |||
* [[{{NAMESPACE}}:CV_22|Consist Lighting (Part 2)]] | |||
* [[{{NAMESPACE}}:CV_24|Consist Deceleration Adjustment]] | |||
* [[{{NAMESPACE}}:CV_156|Dual Prime Mover Delay]] | |||
Latest revision as of 18:26, 2 October 2018
Lua error: Internal error: The interpreter exited with status 1.
NMRA CV 23 - Consist Acceleration Adjustment
This CV contains additional acceleration rate information that is to be added to or subtracted from the base value contained in Configuration Variable #3. This CV will only affect the momentum when CV19 is a non-0 value, meaning the decoder is configured for advanced consisting. The total momentum value can be calculated using the following formula:
([the contents of CV#23] multiplied by [0.896]) divided by (number of speed steps in use)
This is a 7 bit value (bits 0-6) with bit 7 being reserved for a sign bit (0-add, 1-subtract). The product of this formula is added to the value in CV 3. In case of overflow (CV23 + CV3 > 255), the maximum acceleration rate shall be used (255). In case of underflow (CV3 + (-)CV23 < 0) no acceleration shall be used (0). The expected use of this configuration is for changing momentum to simulate differing train lengths/loads. Consisted/MU's tend to pull/push more cars, and therefore can have simulated higher loads by using this configuration.