Diesel Version 5:CV 9: Difference between revisions

From Train Control Systems Documentation
Jump to navigation Jump to search
No edit summary
Line 9: Line 9:


== NMRA CV 9 (PWM Period) ==
== NMRA CV 9 (PWM Period) ==
THIS FEATURE IS NOT (YET) SUPPORTED BY THE WOWDIESEL V5
The value of CV#9 sets the nominal PWM period at the decoder output and therefore the frequency is proportional to the reciprocal of the value. <br>
The value of CV#9 sets the nominal PWM period at the decoder output and therefore the frequency is proportional to the reciprocal of the value. <br>
The recommend formula for PWM period should be: <br><br>
The recommend formula for PWM period should be: <br><br>

Revision as of 12:45, 23 August 2018

Lua error: Internal error: The interpreter exited with status 1.

NMRA CV 9 (PWM Period)

THIS FEATURE IS NOT (YET) SUPPORTED BY THE WOWDIESEL V5

The value of CV#9 sets the nominal PWM period at the decoder output and therefore the frequency is proportional to the reciprocal of the value.
The recommend formula for PWM period should be:

PWM period (uS) = (131 + MANTISSA x 4)x 2 EXP