Difference between revisions of "Diesel Version 5:CV 80"
Jump to navigation
Jump to search
(Created page with "== NMRA CV 80 (Speed Table) == The speed table is defined to be 28 bytes wide, consisting of 28 values for forward speeds. A digital controller that uses this table shall h...") |
|||
Line 1: | Line 1: | ||
− | == NMRA CV 80 | + | == NMRA CV 80 - Speed Table Step 14 == |
The speed table is defined to be 28 bytes wide, consisting of 28 values for forward speeds. A digital controller that uses this table shall have at least 64 voltage drive levels and can have as many as 256 so that a smooth power curve can be constructed. Note that voltage drive levels are specified in integer values, in the same way as most other parameters. This means that a drive level of 1/4 maximum voltage corresponds to 0100000, not 0010000, as you would expect if the number specified a fraction with a fixed denominator, i.e. value 32 out of a fixed 128 levels (see Definitions section). See [[{{NAMESPACE}}:Speed_Table|Speed Table]] for more information on how to setup the Speed Table. | The speed table is defined to be 28 bytes wide, consisting of 28 values for forward speeds. A digital controller that uses this table shall have at least 64 voltage drive levels and can have as many as 256 so that a smooth power curve can be constructed. Note that voltage drive levels are specified in integer values, in the same way as most other parameters. This means that a drive level of 1/4 maximum voltage corresponds to 0100000, not 0010000, as you would expect if the number specified a fraction with a fixed denominator, i.e. value 32 out of a fixed 128 levels (see Definitions section). See [[{{NAMESPACE}}:Speed_Table|Speed Table]] for more information on how to setup the Speed Table. |
Latest revision as of 20:51, 19 September 2018
NMRA CV 80 - Speed Table Step 14
The speed table is defined to be 28 bytes wide, consisting of 28 values for forward speeds. A digital controller that uses this table shall have at least 64 voltage drive levels and can have as many as 256 so that a smooth power curve can be constructed. Note that voltage drive levels are specified in integer values, in the same way as most other parameters. This means that a drive level of 1/4 maximum voltage corresponds to 0100000, not 0010000, as you would expect if the number specified a fraction with a fixed denominator, i.e. value 32 out of a fixed 128 levels (see Definitions section). See Speed Table for more information on how to setup the Speed Table.
Speed Table | |
---|---|
Range of Values | RANGE OF VALUES HERE |
Default Value | DEFAULT VALUE |