Difference between revisions of "Diesel Version 5:CV 122"

From Train Control Systems Documentation
Jump to navigation Jump to search
Line 3: Line 3:
 
|header1 = Crew Alert Light Function
 
|header1 = Crew Alert Light Function
 
|label2 = Range of Values
 
|label2 = Range of Values
|data2 = 0-29
+
|data2 = 0-7
 
|label3 = Default Value
 
|label3 = Default Value
|data3 = 29
+
|data3 = 255
 
}}
 
}}
  
 
== NMRA CV 122 - Crew Alert Light Function ==
 
== NMRA CV 122 - Crew Alert Light Function ==
If a light is installed to be used with the crew alert feature this CV tells the decoder which light to use. For example if light output 1 (green wire) was used to put a light in the cab, then set this CV to a value of 1, use a value of 2 if light output 2 was used, etc. To dissociate the light from the crew alert timer set this CV to a value of 29.
+
If a light is installed to be used with the crew alert feature this CV tells the decoder which light to use.  
 +
{| class="wikitable" style="text-align: center;"
 +
|-
 +
! scope="col"| Light Output
 +
! scope="col"| Value
 +
|-
 +
! scope="row"| F0F/White Wire
 +
| 0
 +
|-
 +
|-
 +
! scope="row"| F0R/Yellow Wire
 +
| 1
 +
|-
 +
|-
 +
! scope="row"| F1/Green Wire
 +
| 2
 +
|-
 +
|-
 +
! scope="row"| F2/Purple Wire
 +
| 3
 +
|-
 +
|-
 +
! scope="row"| F3/Brown Wire
 +
| 4
 +
|-
 +
|-
 +
! scope="row"| F4/Pink Wire
 +
| 5
 +
|-
 +
|-
 +
! scope="row"| F5/Pink/Purple Wire
 +
| 6
 +
|-
 +
|-
 +
! scope="row"| F6/Green/Brown Wire
 +
| 7
 +
|-
 +
|}
 +
To dissociate the light from the crew alert timer set this CV to an invalid value IE 255.
 
<br>
 
<br>
 
<br>
 
<br>

Revision as of 19:52, 27 September 2018

NMRA CV 122
Crew Alert Light Function
Range of Values0-7
Default Value255

NMRA CV 122 - Crew Alert Light Function

If a light is installed to be used with the crew alert feature this CV tells the decoder which light to use.

Light Output Value
F0F/White Wire 0
F0R/Yellow Wire 1
F1/Green Wire 2
F2/Purple Wire 3
F3/Brown Wire 4
F4/Pink Wire 5
F5/Pink/Purple Wire 6
F6/Green/Brown Wire 7

To dissociate the light from the crew alert timer set this CV to an invalid value IE 255.