Diesel Version 5:CV 3: Difference between revisions

From Train Control Systems Documentation
Jump to navigation Jump to search
No edit summary
Line 12: Line 12:
Determines the decoder's acceleration rate.  The higher the value the longer it takes to accelerate.
Determines the decoder's acceleration rate.  The higher the value the longer it takes to accelerate.
<br>
<br>
This CV overwritten when the [http://docs.tcsdcc.com/index.php?title=Momentum_Function "Momentum Function"] is pressed
This CV overwritten when the [[{{NAMESPACE}}:Momentum_Function|"Momentum Function"]] is pressed
The formula for the acceleration rate shall be equal to (the contents  
The formula for the acceleration rate shall be equal to (the contents  
of CV#3*.896)/(number of speed steps  
of CV#3*.896)/(number of speed steps  

Revision as of 19:16, 7 May 2018

Lua error: Internal error: The interpreter exited with status 1.

NMRA CV 3 (Acceleration Rate)

Determines the decoder's acceleration rate. The higher the value the longer it takes to accelerate.
This CV overwritten when the "Momentum Function" is pressed The formula for the acceleration rate shall be equal to (the contents of CV#3*.896)/(number of speed steps in use). For example, if the contents of CV#3 =2, then the acceleration is 0.064 sec/step for a decoder currently using 28 speed steps. If the content of this parameter equals "0" then there is no programmed momentum during acceleration.