Difference between revisions of "Diesel Version 5:CV 189"

From Train Control Systems Documentation
Jump to navigation Jump to search
Line 8: Line 8:
 
}}
 
}}
  
== NMRA CV 189 (Dynamic Brake Min. Speed) ==
+
== NMRA CV 189 - Dynamic Brake Min. Speed ==
 
Since [[{{NAMESPACE}}:Dynamic_Brakes|Dynamic Brakes]] lose braking power at low speed this CV can be used to simulate that. The locomotive won't go below the speed (0-126) in this CV when the dynamic brakes are applied.
 
Since [[{{NAMESPACE}}:Dynamic_Brakes|Dynamic Brakes]] lose braking power at low speed this CV can be used to simulate that. The locomotive won't go below the speed (0-126) in this CV when the dynamic brakes are applied.
  

Revision as of 21:41, 19 September 2018

NMRA CV 189
Dynamic Brake Min. Speed
Range of Values0-126
Default Value10

NMRA CV 189 - Dynamic Brake Min. Speed

Since Dynamic Brakes lose braking power at low speed this CV can be used to simulate that. The locomotive won't go below the speed (0-126) in this CV when the dynamic brakes are applied.

See Also