Difference between revisions of "Diesel Version 5:CV 177"

From Train Control Systems Documentation
Jump to navigation Jump to search
Line 34: Line 34:
 
| OFF
 
| OFF
 
| 4
 
| 4
 +
|-
 +
|-
 +
! scope="row"| Automatic Notching Mechanism Selection
 +
| If enabled, user option bit 4 decides if the prime mover notches will stair step or jump directly between notches. If disabled, the decoder will automatically decide when to use stair stepping or jump notching. The decoder will base this decision on the active [[{{NAMESPACE}}:Momentum_Function|Momentum Mode]].
 +
| OFF
 +
| 8
 +
|-
 +
|-
 +
! scope="row"| Notching Mechanism Selection
 +
| This setting controls whether the [[{{NAMESPACE}}:Notching_Mechanism|Notching Mechanism]] is set to jump-notching or stair-step notching. Manual Notch Mechanism Selection must be active in order to use this setting. If this setting is enabled, the prime mover will stair-step through each notch; If this setting is disabled, the prime mover will jump-notch.
 +
| ON
 +
| 16
 
|-
 
|-
 
|}
 
|}

Revision as of 16:41, 27 September 2018

NMRA CV 177
Sound Options 2
Range of Values0-255
Default Value2

NMRA CV 177 - Sound Options #2

CV177 controls various settings in the WOWDecoder. To program this CV take the values in the values column corresponding to the features you want active and sum them together. Program this value into CV177. See the table below for available options

Feature Description Default Value
Dual Prime Movers Enable this to have prime mover files play simultaneously, used for locomotives like the E8's OFF 1
Dynamic Braking Notch up if enabled the prime mover will notch up multiple times with subsequent presses of the dynamic brake button (F5 by default), if disabled it will go to the Dynamic Brake Notch and stay there when the dynamic brakes are applied ON 2
Reverse Directional Horns If enabled the automatic directional horns (if enabled in Sound Options 1) will reverse, so that the forward horn will play when going reverse. This feature is sometimes useful when a decoder installation has wired the motor in the wrong polarity. Instead of taking apart the locomotive and re-wiring it this feature allows for a software fix. OFF 4
Automatic Notching Mechanism Selection If enabled, user option bit 4 decides if the prime mover notches will stair step or jump directly between notches. If disabled, the decoder will automatically decide when to use stair stepping or jump notching. The decoder will base this decision on the active Momentum Mode. OFF 8
Notching Mechanism Selection This setting controls whether the Notching Mechanism is set to jump-notching or stair-step notching. Manual Notch Mechanism Selection must be active in order to use this setting. If this setting is enabled, the prime mover will stair-step through each notch; If this setting is disabled, the prime mover will jump-notch. ON 16