Difference between revisions of "Diesel Version 5:CV 122"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
|header1 = Crew Alert Light Function | |header1 = Crew Alert Light Function | ||
|label2 = Range of Values | |label2 = Range of Values | ||
− | |data2 = 0- | + | |data2 = 0-7 |
|label3 = Default Value | |label3 = Default Value | ||
− | |data3 = | + | |data3 = 255 |
}} | }} | ||
== NMRA CV 122 - Crew Alert Light Function == | == NMRA CV 122 - Crew Alert Light Function == | ||
− | If a light is installed to be used with the crew alert feature this CV tells the decoder which light to use. | + | If a light is installed to be used with the crew alert feature this CV tells the decoder which light to use. |
+ | {| class="wikitable" style="text-align: center;" | ||
+ | |- | ||
+ | ! scope="col"| Light Output | ||
+ | ! scope="col"| Value | ||
+ | |- | ||
+ | ! scope="row"| F0F/White Wire | ||
+ | | 0 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row"| F0R/Yellow Wire | ||
+ | | 1 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row"| F1/Green Wire | ||
+ | | 2 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row"| F2/Purple Wire | ||
+ | | 3 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row"| F3/Brown Wire | ||
+ | | 4 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row"| F4/Pink Wire | ||
+ | | 5 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row"| F5/Pink/Purple Wire | ||
+ | | 6 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row"| F6/Green/Brown Wire | ||
+ | | 7 | ||
+ | |- | ||
+ | |} | ||
+ | To dissociate the light from the crew alert timer set this CV to an invalid value IE 255. | ||
<br> | <br> | ||
<br> | <br> |
Revision as of 19:52, 27 September 2018
Crew Alert Light Function | |
---|---|
Range of Values | 0-7 |
Default Value | 255 |
NMRA CV 122 - Crew Alert Light Function
If a light is installed to be used with the crew alert feature this CV tells the decoder which light to use.
Light Output | Value |
---|---|
F0F/White Wire | 0 |
F0R/Yellow Wire | 1 |
F1/Green Wire | 2 |
F2/Purple Wire | 3 |
F3/Brown Wire | 4 |
F4/Pink Wire | 5 |
F5/Pink/Purple Wire | 6 |
F6/Green/Brown Wire | 7 |
To dissociate the light from the crew alert timer set this CV to an invalid value IE 255.