Difference between revisions of "Diesel Version 5:CV 28"

From Train Control Systems Documentation
Jump to navigation Jump to search
Line 1: Line 1:
== NMRA CV 28 - Bi-Directional Communication Configuration ==
 
Used to configure decoder’s Bi-Directional communication characteristics when CV29-Bit 3 is set
 
Bit 0 = Enable/Disable Unsolicited Decoder Initiated Transmission
 
“0” = Disabled “1” = Enabled 
 
Bit 1 = Enable/Disable Initiated Broadcast Transmission using Asymmetrical DCC Signal
 
“0” = Disabled “1” = Enabled 
 
Bit 2 = Enable/Disable Initiated Broadcast Transmission using Signal Controlled Influence Signal
 
"0" = Disabled "1" = Enabled
 
Bits 3-5 = Reserved for future use.
 
Bits 6-7 = Flag Bits, Reserved for future use
 
 
*Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be
 
set improperly (i.e. the bit should always contain its default value).
 
 
 
{{Infobox
 
{{Infobox
 
|title = NMRA CV 28  
 
|title = NMRA CV 28  
Line 21: Line 7:
 
|data3 = DEFAULT VALUE
 
|data3 = DEFAULT VALUE
 
}}
 
}}
 +
 +
== NMRA CV 28 - Bi-Directional Communication Configuration (RailCom) ==
 +
Used to configure decoder’s Bi-Directional Communication characteristics when RailCom is enabled in [[{{NAMESPACE}}:CV_29|CV 29]].
 +
<br><br/>
 +
*Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly (i.e. the bit should always contain its default value).
 +
 +
{| class="wikitable" style="text-align: center;"
 +
|-
 +
! scope="col"| Feature
 +
! scope="col"| Description
 +
! scope="col"| Default
 +
! scope="col"| Value
 +
|-
 +
! scope="row"| Channel 1
 +
| If enabled, Channel 1 will broadcast the address.
 +
| ON
 +
| 1
 +
|-
 +
! scope="row"| Channel 2
 +
| If enabled, Channel 2 will send and receive data and provide acknowledgements.
 +
| ON
 +
| 2
 +
|-
 +
|-
 +
! scope="row"| Programming Address 253
 +
| Serves as a programming lock. If this setting is disabled, programming address 253 will be locked.
 +
| ON
 +
| 16
 +
|-
 +
 +
|}

Revision as of 19:05, 2 October 2018

NMRA CV 28
Bi-Directional Communication Configuration
Range of ValuesRANGE OF VALUES HERE
Default ValueDEFAULT VALUE

NMRA CV 28 - Bi-Directional Communication Configuration (RailCom)

Used to configure decoder’s Bi-Directional Communication characteristics when RailCom is enabled in CV 29.

  • Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly (i.e. the bit should always contain its default value).
Feature Description Default Value
Channel 1 If enabled, Channel 1 will broadcast the address. ON 1
Channel 2 If enabled, Channel 2 will send and receive data and provide acknowledgements. ON 2
Programming Address 253 Serves as a programming lock. If this setting is disabled, programming address 253 will be locked. ON 16