Difference between revisions of "Diesel Version 5:CV 27"
(Created page with "== NMRA CV 27 (Decoder Automatic Stopping Configuration) == Used to configure which actions will cause the decoder to automatically stop. Bit 0 = Enable/Disable Auto Stop in...") |
|||
Line 3: | Line 3: | ||
Bit 0 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the | Bit 0 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the | ||
right rail. | right rail. | ||
− | “0” = Disabled “1” = Enabled | + | “0” = Disabled “1” = Enabled |
Bit 1 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail. | Bit 1 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail. | ||
“0” = Disabled “1” = Enabled | “0” = Disabled “1” = Enabled | ||
Line 11: | Line 11: | ||
Bit 4 = Enable/Disable Auto Stop in the presence of reverse polarity DC | Bit 4 = Enable/Disable Auto Stop in the presence of reverse polarity DC | ||
“0” = Disabled “1” = Enabled | “0” = Disabled “1” = Enabled | ||
− | Bit 5 = Enable/Disable Auto Stop in | + | Bit 5 = Enable/Disable Auto Stop in the presence forward polarity DC. |
− | |||
“0” = Disabled “1” = Enabled | “0” = Disabled “1” = Enabled | ||
Bits 6-7 = Reserved for future use. | Bits 6-7 = Reserved for future use. |
Revision as of 16:11, 25 June 2018
NMRA CV 27 (Decoder Automatic Stopping Configuration)
Used to configure which actions will cause the decoder to automatically stop. Bit 0 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the right rail. “0” = Disabled “1” = Enabled Bit 1 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail. “0” = Disabled “1” = Enabled Bit 2 = Enable/Disable Auto Stop in the presence of an Signal Controlled Influence cutout signal. “0” = Disabled “1” = Enabled Bit 3 = Reserved for Future Use Bit 4 = Enable/Disable Auto Stop in the presence of reverse polarity DC “0” = Disabled “1” = Enabled Bit 5 = Enable/Disable Auto Stop in the presence forward polarity DC. “0” = Disabled “1” = Enabled Bits 6-7 = Reserved for future use.
- Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be
set improperly (i.e. the bit should always contain it’s default value).
Decoder Automatic Stopping Configuration | |
---|---|
Range of Values | RANGE OF VALUES HERE |
Default Value | DEFAULT VALUE |