Difference between revisions of "Diesel Version 5:CV 238"

From Train Control Systems Documentation
Jump to navigation Jump to search
(Created page with "{{Infobox |title = NMRA CV 238 |header1 = Dual Enabled Functions Part 1 |label2 = Range of Values |data2 = 0-255 |label3 = Default Value |data3 = 3 }} == NMRA CV 238 (Dual En...")
 
Line 10: Line 10:
 
== NMRA CV 238 (Dual Enabled Functions Part 1) ==
 
== NMRA CV 238 (Dual Enabled Functions Part 1) ==
 
This controls whether functions are [[{{NAMESPACE}}:Dual_Enabled_Functions|Dual Enabled]]. To dual enable a light function take the value in the corresponding columns and sum them together, program that value into the CV
 
This controls whether functions are [[{{NAMESPACE}}:Dual_Enabled_Functions|Dual Enabled]]. To dual enable a light function take the value in the corresponding columns and sum them together, program that value into the CV
 +
 +
'''@TODO''' ''Theres no need to have F0F and F0R? That is redundant since this is based off of function buttons and not function outputs?''
  
 
{| class="wikitable" style="text-align: center;"
 
{| class="wikitable" style="text-align: center;"
 
|-
 
|-
! scope="col"| Light Output
+
! scope="col"| Function Button
! scope="col"| Wire color (for wired decoders)
 
 
! scope="col"| Value
 
! scope="col"| Value
 
|-
 
|-
 
|-
 
|-
 
! scope="row"| F0 Forward
 
! scope="row"| F0 Forward
| White
 
 
| 1
 
| 1
 
|-
 
|-
 
|-
 
|-
 
! scope="row"| F0 Reverse
 
! scope="row"| F0 Reverse
| Yellow
 
 
| 2
 
| 2
 
|-
 
|-
 
|-
 
|-
 
! scope="row"| 1
 
! scope="row"| 1
| Green
 
 
| 4
 
| 4
 
|-
 
|-
 
! scope="row"| 2
 
! scope="row"| 2
| Purple
 
 
| 8
 
| 8
 
|-
 
|-
 
! scope="row"| 3
 
! scope="row"| 3
| Brown
 
 
| 16
 
| 16
 
|-
 
|-
 
! scope="row"| 4
 
! scope="row"| 4
| Pink
 
 
| 32
 
| 32
 
|-
 
|-
 
! scope="row"| 5
 
! scope="row"| 5
| Pink/Purple
 
 
| 64
 
| 64
 
|-
 
|-
 
! scope="row"| 6
 
! scope="row"| 6
| Green/Brown
 
 
| 128
 
| 128
 
|-
 
|-

Revision as of 19:27, 11 September 2018

NMRA CV 238
Dual Enabled Functions Part 1
Range of Values0-255
Default Value3

NMRA CV 238 (Dual Enabled Functions Part 1)

This controls whether functions are Dual Enabled. To dual enable a light function take the value in the corresponding columns and sum them together, program that value into the CV

@TODO Theres no need to have F0F and F0R? That is redundant since this is based off of function buttons and not function outputs?

Function Button Value
F0 Forward 1
F0 Reverse 2
1 4
2 8
3 16
4 32
5 64
6 128