Diesel Version 5:CV 115

From Train Control Systems Documentation
Revision as of 20:53, 5 September 2018 by Johnd (talk | contribs)
Jump to navigation Jump to search
NMRA CV#115
Motor Delay Reset Time
Range of Values0-255
Default Value0

NMRA CV #115 (Motor Delay Reset Time)

This CV controls how long the motor will delay after a speed command is received before enacting it. This feature allows more prototypical operation when automatic directional sounds are enabled so that the directional sound can play before the locomotive moves. This is for safeties sake so that any person in harms way will have a heads up that they need to get out of the way.

To set the delay time multiply the desired time (in seconds) by 2 and program that value into CV115. For example if you want to give 2 seconds from when the speed command is sent/directional sound starts playing enter a value of 4 into CV115